Main process parameters of 0.5T induction melting furnace-songdao induction heating equipment manufacturer
Main process parameters of 0.5T induction melting furnace
Author:admin time:2019-08-23 07:03

image.png

Main process parameters of 0.5T induction melting furnace

Induction melting furnace

Rated Capacity

t

0.5

Maximum capacity

t

0.7

Iron temperature

°C

1450~1 8 00

Meltingpower consumption (hot furnace, molten steel)

Kwh/t

650 ±5% in the case of pure melting .

Melting consumption (heating furnace, iron water)

Kwh/t

600 ±5% in the case of pure melting .

Melting rate (steel water)

h/t

0.5

Cooling water

Influent flow

M3/h

≥ 40

Inlet pressure

MPa

0.3

Inlet temperature

°C

≤ 32

Return water temperature

°C

≤ 52

Tilting method


Hydraulic tilting

Rectifier transformer

Product number

ZS -type

Voltage combination

10KV/380V/380V secondary side Δ /Y double winding, star winding midpoint extraction

Transformer capacity

KVA

1000kva (two shared)

Primary voltage

KV

10 ± 5% KV

Secondary voltage

V

380 × 2

Phase

Primary side phase secondary side phase connected to intermediate frequency power supply cabinet

frequency

HZ

50

Connection group

DdOY11 ( secondary side line voltage phase difference of 30 ° )

Short circuit impedance

9%

cooling method

ONAN , cooling medium: 25th transformer oil

Pressure regulation method

Automatic non-excitation voltage regulation ,

effectiveness

98%,

Executive standard

JB/T8636-1997 "Power Converter Transformer"

Rectifier transformer

The rectifier transformer is used to reduce the primary high voltage to the input voltage suitable for the intermediate frequency power supply. The device uses a dedicated high-impedance oil-immersed self-cooling rectifier transformer, the model is ZS series. The primary voltage of the transformer is 10KV and the secondary voltage is 380V . The rectifier transformer is equipped with a gas relay and a oil temperature relay table, which can be interlocked with the high voltage cabinet. When the transformer has gas or oil temperature exceeding the standard, the high voltage input can be automatically cut off and an alarm is issued.


Intermediate frequency power supply

 

 

 

rated power

KW

5 00

DC voltage

V

102 4

DC

A

488

Number of commutating pulses

pulse

12

Cooling water

Influent flow

M3/h

≥ 15

Inlet pressure

MPa

0.25

Inlet temperature

°C

≤ 32

Return water temperature

°C

≤ 42

IF voltage

V

2400

IF frequency

Hz

800 can be fine-tuned

Power factor

C OS φ

0.95 for any power usage

Inverter form


Series inverter

noise

dB

85dB

Starting success rate


100%














 


TEL
15038554363 18037961302