Detailed configuration list of KGPS-1.5T-2 induction melting furnace
1. Electric cabinet:
1. Rated phase-in voltage: 380V, intermediate frequency output voltage 900V, DC current: 2000A, power: 600KW
2. KK SCR 2000A/1600V 8 pcs
3. KP SCR 2000A/1600V 6 pcs
4. Air switch 2500A
5. Installed copper bar 80mm X 6mm
6. Reactor (copper pipe diameter 16mm, wall thickness 1.5mm coil, 8 pieces)
6. Intelligent system
2. Capacitor cabinet:
capacitor 2000KF /750V 8 units
Three, stove
Reducer: 531
furnace shell: diameter 1330 mm high 1300 mm.
induction coil (weight: 200 kg): copper tube 20 mm X 40 mm X 3 mm inner diameter 750 mm 18 coils.
Features:
1. Intelligent system, fast protection speed, durable thyristor, good starting performance, stable work and convenient operation.
2. Using large copper busbars to install the machine, saving power; using a booster circuit, the voltage at both ends of the electric furnace can reach 1800V (twice the output voltage of the electric cabinet), water cables and induction coils are small in loss and energy saving.