First, the electric cabinet:
1, rated phase voltage: 700V, intermediate frequency output voltage 1200V, DC current (maximum): 1800A, power (maximum): 900KW
2, KK thyristor 1500A/2000V 8
3, KP thyristor 1800A/2500V 6
4, reactor (copper tube diameter 15mm, wall thickness 1.5mm coil, 6)
5, constant power control system
Second, the capacitor cabinet:
Capacitor 2000KF / 1200V 7 sets
Induction melting furnace Reducer: 431
Furnace shell: diameter 1230 mm high 1350 mm.
Induction ring: Copper tube 25 mm X 40 mm X 3.5 mm Inner diameter 730 mm 15 turns.
Features:
Commonly used type, fast protection, good starting performance, stable work and low price.