Technical requirements for induction melting furnace compensation capacitor cabinet-songdao induction heating equipment manufacturer
Technical requirements for induction melting furnace compensation capacitor cabinet
Author:induction furnace time:2019-11-12 10:21

Technical requirements for induction melting furnace compensation capacitor cabinet

The induction melting furnace compensation capacitor cabinet has a solid overall structure and beautiful appearance. The double-layer mica insulation technology is used for the insulation treatment of the capacitor. Even if water is sprayed on the capacitor accidentally, the insulation strength of the cabinet can be ensured.

In order to reduce the loss of the high current loop , the compensating capacitor bank is installed in the basement as close as possible to the induction melting furnace All capacitors adopt new high-capacity non-toxic medium water-cooled RFM series electric heating capacitors, which have the advantages of large single capacity, low dielectric loss and small floor space. The capacitor cabinet is installed near the furnace body, which can reduce the loss of the tank and improve the efficiency. A temperature monitoring point is installed in the capacitor cabinet to ensure stable operation of the power supply.

Main structure and performance characteristics:

Serial number

project

performance

1

Cabinet

Non-standard GGD type  

2

Configuration capacity

60000 Kvar RMF1.6-2000-0.5S 30 units

3

Framework

Using high quality 2.0mm cold rolled steel

4

Mounting screw material

Carbon steel 4.8 and 8.8 Ji

5

Protection level

IP54 protection net

6

Slot road

Using T2 . 6 * 150 cooled parent row

7

Channel gap

A- 40 mm

8

Channel insulation

The high-insulation struts are reinforced in the middle to prevent short circuit when the electromagnetic force is large when the busbar is long .

9

bolt

Use copper bolts , copper caps, and prevent heat.

10

Capacitor case

Using the aluminum plate. This can greatly reduce the heat generated by the eddy current.

11

Measured capacitance and rated value difference

Not exceeding ±10% of rated value

12

Withstand voltage

 

Power frequency communication 2.15 times rated voltage, 10 seconds of experiment

 

13

Electric capacitor

It is mainly composed of a core and a casing, which are filled with excellent impregnating agent, the core is welded with a cooling water pipe , and the power supply container is cooled.

14

Executive standard

Capacitor performance in accordance with GB/T3984.1-2004 "Electrothermal capacitor IEC110 (1973) "frequency 40 ~ 24000HZ induction heating device capacitors" .

http://www.songdaokeji.com/plus/list.php?tid=22

http://www.songdaokeji.com/


TEL
15038554363 18037961302