8 tons induction heating furnace technical parameters and configuration-songdao induction heating equipment manufacturer
8 tons induction heating furnace technical parameters and configuration
Author:admin time:2019-09-01 09:51

One set of medium frequency power supply with a power of 5000 kw is equipped with two sets of tons of melting furnace . Use a 6300KVA dedicated rectifier transformer for 5000KW intermediate frequency power supply,

First , 8 tons induction heating furnace main technical parameters

Project

Parameter

Remarks

Power line voltage

950V, 50Hz

User grid voltage 10KV

Rated Capacity

8T

5000KW power melting

rated power

500 0 KW

6-phase 12-pulse control system

Rated intermediate frequency

500 Hz


Rated temperature

1650 ° C


Melting rate

About 8T/H

Continuous use of the melting furnace

Unit power consumption

About 550-600kwh/T

Continuous use of the melting furnace

Power cooling cycle water consumption

15T/H

Continuous use of the melting furnace

Furnace cooling cycle water consumption

10T/H

Continuous use of the melting furnace

Hydraulic station capacity

1000 L


Transformer model

ZSS-6300 /10KV/950

A dedicated rectifier transformer ( for 6300KW )

Hydraulic medium

No. 46 hydraulic oil


Water supply pressure

0.2-0.3 MPa

To the electric furnace port position

Hydraulic station working pressure

10.5 MPa

Up to 12 MPa

Inlet temperature

£ 35°C


Effluent temperature

£ 55°C


 

4. 8T/5000KW induction heating furnace project engineering configuration

 

Name

Model and notes

Quantity

IF power cabinet

5000KW with 8 tons of furnace

 

1 set

Capacitor bank

Leakage alarm device

Furnace body

8T melting furnace body

2 sets

Model


Water cooled cable

Water-cooled cable side outlet

2 sets

Hydraulic station system

One pump and one motor

1 set

Tilting console

Rexroth series components

1 set

Special rectifier transformer ZS-6300/950V×2



Equipment technical drawings


1 set

Equipment instruction manual 


1 set

Certificate and inspection report


1 set

Remarks: 1) With the 3-phase 6-pulse double rectification control system, the 5th, 7th, 11th, and 13th harmonics are eliminated, which greatly reduces the harmonic interference of the power grid.

2) The use of a fully enclosed cooling tower can improve the cooling effect of the system and the service life of the equipment without the need to build a pool.

 

image.png