Medium frequency induction heating equipment use and maintenance-songdao induction heating equipment manufacturer
Medium frequency induction heating equipment use and maintenance
Author:admin time:2019-08-27 09:21

1 IF induction heating equipment before heating

     Before turning on the power, test the water first, and check if the water pressure is satisfactory and there is no water leakage.

2 IF induction heating equipment heating

2.1 During the operation of the induction furnace, the cooling water should be kept open. The water temperature, water pressure and water quality should meet the requirements of 3.5.2~3 above.

2.2 After the heating is completed, turn off the power supply. Do not stop the cooling water immediately. Only when the furnace material is pushed out, the furnace lining can be completely cooled before it can stop water.

3.3 If there is a sudden power failure during the heating process, remember to open the spare water until the charge is pushed out and the lining is completely cooled.

3 medium frequency induction heating equipment lubrication

All the moving parts of the induction heating machine that need to be lubricated should always check the lubrication and add lubricant regularly.

4 IF induction heating equipment common faults and troubleshooting

A, the water cooling system leaks, may need to be replaced due to aging of the water hose, or the stainless steel clip does not work, you need to put a layer of cloth or other non-magnetic materials between the clip and the water hose to tighten. The copper tube leaks and is repaired by copper-zinc welding rod. After welding, it is required to pass the water pressure of 1Mpa for 5 minutes without leakage.

B. Regularly check the insulation. If the insulation is found damaged, it should be replaced and repaired in time. Fasten the conductive connecting bolts regularly.

image.png

TEL
15038554363 18037961302